🌑️ Env Test Plan Builder
Test item:  Β·  Model:  Β·  Level:
Doc No.
Revision
Test date

Document & Test Item Information

Document title
Document No.
Revision
Project / Mission
Test facility / Location
Test item (DUT)
Part No.
Serial No.
Model

Purpose / Scope

Test Factors & Parameters

Test level Β· Standard change in section 1 ↑
Operating Temperature
LowΒ°C
HighΒ°C
Survival Temperature
LowΒ°C
HighΒ°C
Test MarginAccept.Qual.
Low (Β°C beyond Op. Low)
High (Β°C beyond Op. High)
Test Low Temperature
Test High Temperature

Test Profile Parameters

Number of cyclescycles
First extreme
Ramp rateΒ°C/min
Cycle 1 start time
Pre-test is extended so Cycle 1 starts on a round time. You can also type any time into Planned start / Planned end in the sequence table.
High & Low dwell (intermediate cycles)min
Dwell – first & last cyclemin
Pre-test (ambient hold)min
Post-test (ambient hold)min
Advanced settings – test conditions, ambient, overnight pause
Test Conditions
Environment / Pressure
Tolerance – Hot
Tolerance – Cold
Stabilization criterion
Ambient / start temp.Β°C
Ambient pause (e.g. overnight)
Pause after cyclecycle
Pause durationmin
Ramp tolerance

Test Profile Time axis

πŸ–±οΈ Click anywhere on the profile to add a Functional Test at that time Β· Drag a green band to move it Β· Click a band to edit it.

Cycle Plan – name each cycle (what is tested). Click a cycle title on the chart to jump here.

Test profile Operating limits Survival limits Ambient βœ– FT n = Functional test window

Test Sequence & As-Run Log

Functional Test Plan

Vibration Test Parameters

Test level Β· Standard change in section 1 ↑
Test item masskg
Test configuration
Axis order
Launch (longitudinal) axis of the item
Test levels from
Test tolerances
Random / Sine test
Advanced settings – mounting, control, notching, abort limits
Mounting / interface
Control strategy
Notching / force limiting
Random alarm / abortΒ± dB  /  Β± dB

Vibration Level Library & Envelope

Test level Β· Standard change in section 1 ↑
Compare the vibration environments of the launch vehicles and standards, tick one or more to see their envelope, then press Apply envelope to use it as this plan's test levels. Levels are shown at the test level selected below.
Module mass (from Vibration Test Parameters)
Values transcribed from the user guides listed (spacecraft interface). Always confirm against the mission ICD / coupled-loads analysis.

Random Vibration

Test Grms (this level)
Duration
Levels from
Advanced settings – presets, source, margins per level, durations, pre-level runs
Base spectrum presets:
Base spectrum = MPE / acceptance level. Source
Level vs. baseAccept.Qual.PFM
PSD offset (dB)
Duration per axis (s)
Pre-level runs (dB below test)
Pre-level durations
Test Grms (current level)
Grms tolerance (Β±10 %)

Breakpoints

Test levelBase (MPE / acceptance)Tolerance bandAbort limits

Sine Vibration

Test level
Sweep
Levels from
Advanced settings – source, factors & sweep rates per level, direction, pre-level runs
Limit level source
Level vs. limitAccept.Qual.PFM
Test factor (Γ— limit)
Sweep rate (oct/min)
Sweep direction
Pre-level runs (dB below test)

Limit level profile

Test levelLimit levelΒ±10 % tolerance

Tip: with πŸ“¦ Import 3D model (STL / OBJ – SolidWorks: File β†’ Save As β†’ STL) the views are generated automatically and a sensor placed on one view appears in every view (dashed marker = hidden behind the part).
1) Click Add picture (or drop / paste with Ctrl+V) to attach a photo or CAD view of the test item. 2) With Place mode ON, click on the picture to place a sensor. Drag markers to adjust. 3) Fill in details in the table and tick Installed during setup.
Advanced settings – sensor name & label prefix
Sensor name Prefix (e.g. Thermocouple / TC, Accelerometer / ACC)

Sensor List

Test Equipment

Test Procedure (Step-by-step)

Tick GO/NO-GO for hold points that need a decision before continuing. During the test tick βœ“ and fill Operator / Witness.

Test Flow Chart

Generated automatically from the Test Procedure steps – edit the steps (or tick GO/NO-GO) and the chart follows. Click a box to jump to its step.

Run Sequence & As-Run Log

Advanced settings – resonance survey level, schedule estimate, FT between axes
Low-level sine survey (resonance search)
Frequency range – Hz
Levelg (0-pk)
Sweep rateoct/min
Schedule estimate
First mounting & set-upmin
Axis change (rotate / re-mount)min
Overhead per runmin
Functional test durationmin
Functional test between axes

Run table

Resonance Survey Comparison (Data Sheet)

Pass if |Ξ”f| < % and |Ξ”A| < % for modes with effective mass > % (ECSS-E-ST-10-03C 5.5.2: 5 % / 20 % / 10 %). Compare the first (pre) and last (post) survey of each axis.

Functional Test – Pre / Post Vibration

Pass / Fail Criteria, Safety & Notes

Pass / Fail criteria

Safety notes

Anomalies / Deviations / NCR

Test Execution Sign-off

Appendix A – Applicable Documents & Standard Compliance

A.1 Applicable & Reference Documents

Compliance tables follow the applicable standard chosen in section 1.

A.2

Requirements are short paraphrases for checking this plan – the official text (free download at ecss.nl) governs. Plan check is evaluated automatically from this document; set Compliance (C = Compliant, PC = Partially, NC = Non-compliant, N/A) and justify deviations in Remarks.

Created by Chatjakkrit Janyasuthiwong